(1) The Board of Boiler Rules shall adopt rules to provide for the inspection of the installation, operation and condition of boilers and pressure vessels that are used or proposed for use in this state and not made exempt from periodic inspection under ORS 480.510 to 480.670. (2) Pressure piping that is nonboiler external piping, but that excludes potable water nonboiler external piping, shall be inspected on installation only and may not thereafter be considered as part of the boiler for the purposes of any subsequent inspections required by this section. (3) If a hydrostatic test is necessary to determine the safety of a boiler or pressure vessel, the test shall be made by the owner or user of the boiler or pressure vessel and witnessed by a deputy or special inspector. (4) All boilers and pressure vessels to be installed in this state shall be inspected during construction: (a) By an inspector authorized to inspect boilers in this state or authorized under ORS 455.715 to 455.740 to perform inspections of boilers and pressure vessels identified by rule as provided in ORS 480.525 (5); or (b) If constructed outside of the state, by an inspector holding a certificate of competency issued by a state that has a standard of examination substantially equal to that of this state. [1961 c.485 §17; 1969 c.582 §10; 1973 c.830 §3a; 1983 c.676 §11; 1991 c.518 §9; 2007 c.487 §6; 2009 c.696 §14]
Administrative rules citing this section
- OAR 918-225-0240: Definitions — implements
- OAR 918-225-0300: Exemptions for Fired Water Heaters — implements
- OAR 918-225-0300: Exemptions for Fired Water Heaters — authority
- OAR 918-225-0320: Exemptions for Refrigerant or Air Conditioning Pressure Vessels — implements
- OAR 918-225-0320: Exemptions for Refrigerant or Air Conditioning Pressure Vessels — authority
- OAR 918-225-0330: Exemptions for Unfired Pressure Vessels With an Inside Diameter of Six Inches and Less — implements
- OAR 918-225-0330: Exemptions for Unfired Pressure Vessels With an Inside Diameter of Six Inches and Less — authority
- OAR 918-225-0340: Exemptions for Pressure Containing Parts of Piping Components — implements
- OAR 918-225-0340: Exemptions for Pressure Containing Parts of Piping Components — authority
- OAR 918-225-0350: Exemptions for Hot Water Storage Tanks — implements
- OAR 918-225-0350: Exemptions for Hot Water Storage Tanks — authority
- OAR 918-225-0360: Exemptions for Certain Pressure Vessels — implements
- OAR 918-225-0360: Exemptions for Certain Pressure Vessels — authority
- OAR 918-225-0370: Exemptions for Coil-Type Water Boilers — implements
- OAR 918-225-0370: Exemptions for Coil-Type Water Boilers — authority
- OAR 918-225-0380: Exemptions for Refrigeration Chillers — implements
- OAR 918-225-0380: Exemptions for Refrigeration Chillers — authority
- OAR 918-225-0430: Adopted Oregon Boiler and Pressure Vessel Specialty Code — implements
- OAR 918-225-0540: Scope of Special Inspector’s Authority — implements
- OAR 918-225-0540: Scope of Special Inspector’s Authority — authority
- OAR 918-225-0590: Inspection Cycle Extension Program — implements
- OAR 918-225-0590: Inspection Cycle Extension Program — authority
This rule cites
- ORS 480.510 — resolved
- 480.670 — resolved
- ORS 455.715 — resolved
- 455.740 — resolved
- ORS 480.525 — resolved