OAR 812-008-0209: Electrical
Edition: Current OARD snapshotEffective: 2011-05-01Last verified: 2026-09-07
(1) The Oregon certified home inspector shall observe: (a) Service entrance conductors; (b) Service equipment, grounding equipment, main overcurrent device, and distribution panels; (c) Amperage and voltage ratings of the service; (d) Branch circuit conductors, their overcurrent devices, and the compatibility of their amperages and voltages; (e) The operation of a representative number of installed ceiling fans, lighting fixtures, switches, and receptacles located inside the house, garage, and on the dwelling’s exterior walls; (f) The polarity and grounding of all receptacles within six feet of interior plumbing fixtures, and all receptacles in the garage or carport, and on the exterior of inspected structures; (g) The operation of ground fault or arc fault circuit interrupters; (h) Smoke alarms; and (i) Carbon monoxide detectors. (2) The Oregon certified home inspector shall describe: (a) Service amperage and voltage; (b) Service entry conductor materials; and (c) Service type as being overhead or underground; (3) The Oregon certified home inspector shall report: (a) Any observed 110 volt aluminum branch circuit wiring; and (b) The presence or absence of smoke alarms, and operate their test function, if accessible, except when detectors are part of a central security system. (4) The Oregon certified home inspector is not required to: (a) Insert any tool, probe, or testing device inside the panels; (b) Test or operate any overcurrent device or safety device in the electrical service panel or elsewhere that may adversely affect the personal property of the resident; (c) Dismantle any electrical device or control other than to remove the covers of the main or auxiliary distribution panels; (d) Observe: (A) Low-voltage systems except to report the presence of solenoid-type lighting systems; (B) Security system devices or heat detectors; (C) Telephone, security, TV, intercoms, lightening arrestors or other ancillary wiring that is not a part of the primary electrical distribution system; or (D) Built-in vacuum equipment.
Official history and status
Statutory/Other Authority: ORS 670.310, 701.235, 701.350 & 701.355
Statutes/Other Implemented: ORS 105.838(1), 701.350 & 701.355
History: CCB 2-2011, f. 4-28-11, cert. ef. 5-1-11 Renumbered from 812-008-0080, CCB 5-2005, f. 8-24-05, cert. ef. 1-1-06 CCB 7-2002, f. 6-26-02 cert. ef. 7-1-02 CCB 6-2001, f. & cert. ef. 9-27-01 CCB 9-2000, f. & cert. ef. 8-24-00 CCB 7-2000, f. 6-29-00, cert. ef. 7-1-00 CCB 2-2000, f. 2-25-00, cert. ef. 3-1-00 CCB 8-1998, f. 10-29-98, cert. ef. 11-1-98 CCB 1-1998, f. & cert. ef. 2-6-98
This rule cites
No citations extracted.
Cited by
No inbound citations found.
Official source: https://secure.sos.state.or.us/oard/