OAR 340-234-0540: Board Products Industries (Veneer, Plywood, Particleboard, Hardboard): Testing and Monitoring
Edition: Current OARD snapshotEffective: 2019-05-16Last verified: 2026-09-07
All source tests must be done using the DEQ Source Sampling Manual. [NOTE: The DEQ Source Sampling Manual is published with OAR 340-200-0035.] (1) Veneer dryers, wood particle dryers, fiber dryers and press/cooling vents must be tested using DEQ Method 7. (2) Air conveying systems must be tested using DEQ Method 8. (3) Fuel burning equipment must be tested using DEQ Method 5. When combusting wood fuel by itself or in combination with any other fuel, the emission results are corrected to 12% CO2. When combusting fuels other than wood, the emission results are corrected to 50% excess air. [NOTE: This rule is included in the State of Oregon Clean Air Act Implementation Plan that EQC adopted under OAR 340-200-0040.]
Official history and status
Statutory/Other Authority: ORS 468.020, 468A.025 & 468A.070
Statutes/Other Implemented: 468A.025 & 468A.070
History: DEQ 13-2019, amend filed 05/16/2019, effective 05/16/2019 DEQ 7-2015, f. & cert. ef. 4-16-15
This rule cites
- OAR 340-200-0035 — resolved
- This rule — target_record_not_published
- OAR 340-200-0040 — resolved
Cited by
No inbound citations found.
Official source: https://secure.sos.state.or.us/oard/